Today's KNOWLEDGE Share : PIGMENT DISPERSION IN COATINGS | PART 5

Today's KNOWLEDGE Share

PIGMENT DISPERSION IN COATINGS | PART 5

Hegman Grind vs. Particle Size: Are We Measuring the Same Thing?

A good Hegman reading does not necessarily mean a pigment dispersion has reached its optimum particle size distribution.

These methods assess different aspects of dispersion quality.


1. What does the Hegman gauge actually measure?

The Hegman grind gauge is a practical quality-control tool for evaluating dispersion fineness in coatings. It helps identify coarse particles & agglomerates that produce visible traces as the sample is drawn down across a calibrated groove.

However, it does not measure the complete particle size distribution or directly quantify dispersion stability. A satisfactory reading does not describe the entire pigment population.

2 .What do instrumental methods add?

Modern particle characterization techniques provide complementary information:

Laser Diffraction (LD)

Measures particle size distribution over a broad range. It is useful for evaluating coarse populations & changes in agglomerate size.

Dynamic Light Scattering (DLS)

Estimates hydrodynamic particle size in suitable dilute dispersions, particularly in the submicron and nanoscale range. Results are sensitive to larger particles & sample preparation.

Optical and Electron Microscopy

Allow direct visualization of particle morphology depending on resolution & preparation, aggregates/ agglomerates. SEM & TEM reveal structural details that a grind gauge cannot.

Analytical Centrifugation

Helps characterize sedimentation behavior & dispersion stability by monitoring concentration profiles over time.

Each technique answers a different question; selection depends on pigment type, formulation & the information required.

3. Why can the results differ?

A grind gauge and a particle size analyzer do not measure exactly the same property.

For example, a dispersion may achieve a satisfactory Hegman reading while laser diffraction still detects a broader coarse-particle or agglomerate population.

Results can also change with dilution, dispersion energy & sample preparation.

The measurement method must match the question being asked.

4. What should formulators evaluate?

A more complete assessment combines complementary measurements:

• Hegman: coarse-particle control
• Particle size distribution: size range & distribution profile
• Microscopy: morphology and structural features
• Storage testing: changes over time
• Viscosity & color strength: formulation performance

The objective is not to replace a simple, effective quality-control tool with a more sophisticated instrument in every case. It is to understand what each measurement can—and cannot—tell us.

Sample preparation & measurement conditions should therefore be standardized before comparing results.

A single measurement cannot fully describe dispersion quality.

The best evaluation combines the right analytical methods with actual coating performance.

source : Ernesto Muñiz Mata

Comments

Popular posts from this blog

Today's KNOWLEDGE Share : Robotic 3D printing can compete with traditional boatbuilding

Today's KNOWLEDGE Share : A BUG IN INJECTION MOLDING

𝐓𝐨𝐝𝐚𝐲'𝐬 𝐊𝐍𝐎𝐖𝐋𝐄𝐃𝐆𝐄 𝐒𝐡𝐚𝐫𝐞 : 𝐀𝐍𝐓𝐈-𝐎𝐗𝐈𝐃𝐀𝐍𝐓 – 𝐓𝐡𝐞𝐫𝐦𝐚𝐥 𝐚𝐧𝐝 𝐏𝐫𝐨𝐜𝐞𝐬𝐬 𝐏𝐫𝐨𝐭𝐞𝐜𝐭𝐢𝐨𝐧